Cargadores de baterías serie ik

Our iK series industrial battery chargers are designed with SCR thyristor switching technology to generate a correct voltage level for the control in the direct current output, which is adjusted by means of a phase control through a microprocessor that synchronizes the shots to 6 pulses increasing its reliability of operation.

Its robustness, efficiency, minimum maintenance, remote monitoring and ease of use make it possible to operate in any industrial environment, providing the possibility of interacting in the floating charge and equalization of open or sealed batteries of: acid lead, nickel cadmium or lithium.

It has a telecommunications protocol DNP3 and IEC 61850 through the RS232, RS 485 and Ethernet ports, making it an easy-to-remotely monitored equipment and increasing its usability.

The design of the enclosure is determined according to the characteristics of the iK series industrial charger required by our clients.

  • Output voltage range of 120 VCD
  • Enclosure to wall or floor
  • Enclosure with NEMA 3 standard to NEMA 12
  • Indoor or Outdoor Enclosure
  • Battery bank included
  • Front access for easy maintenance
  • Safety protection up to IP 55


Technical specifications


serie ik
  • Voltage ranges: floating and equalization (Independent and adjustable)
  • Input voltage: 2220-440, 240-480 3-wire and neutral
  • Output voltage: nominal 12, 24, 48, 130 and 260 VCD
  • Current range: 6-400 amperes with current limit
  • Frequency: 60 HZ +/-5%
  • Adjustment range: +/- 0.25%
  • Temperature: 0° to 50°C
  • Operating altitude: 2,500 meters above sea level
  • Electrical noise: maximum 1% RMS with a battery capacity 4 times > than rated current, typical 205% RMS without battery and 32
  • Audible noise: 60db at 1.5 meters distance
  • User interaction:it has touch-screen to check and adjust the parameters
  • Operation: Parallel operating capacity
  • Special designs for single-phase industrial chargers.

Protections

Input:
  • Thermomagnetic switch
  • Peak suppressor
  • Snnuber in power modules
Output:
  • Totally isolated system
  • High Voltage Input Disconnection
  • High Voltage Output Disconnection

Alarm system

  • Major alarm
  • Minor alarm
  • Absence of alternating current
  • Low voltage direct current
  • Charge fault
  • Short circuit fault
  • Positive grounding
  • Negative grounding
  • Recharge cycle interruption
  • Recharge cycle termination
  • Manual operation
  • Temperature

Applications

  • Transmission and distribution of energy
  • Transport
  • Voice and data center
  • Treatment plants
  • Digital monitoring and control
  • Refineries
  • Gas Pipelines
  • Mining
  • Telecommunications
  • Hospitals


Custom designs on iK series chargers