High reliability in battery systems

Vent Pro VRLA

Sealed industrial batteries with regulated valve, operation with electrolyte based on potassium hydroxide, has a low water consumption and its service of operation is optimal even in high temperatures. Their special gas separators ensure minimum water loss, exceeding the requirements of the IEC 62259 standard and operating without any problem.

Characteristics
  • Bag Plates
  • Separator that improves the recombination of gases
  • Elimination of thermal problems
  • Special design of the valve with low pressure
  • Vertical mounting
  • High impact resistance
  • Operation with electrolyte of 1,200 gr/cm3 density at 25°C
  • Compliance with IEC 62259
Based on the application and needs of our clients, there are two types of plates, which are:
1. L-type cells from 15 to 1680 Ah for low discharge applications, from 3 to 100 hours.
  • Petrochemicals
  • Emergency lights
  • Rural environments
Capacity chart     Contact for sale
2. M-type cells for low discharge applications, from 30 minutes to 3 hours.
  • Starting engines
  • Instrumentation and control processes
  • UPS
  • Driving force
  • Emergency lights
Capacity chart     Contact for sale

VRPP

Sealed industrial batteries, designed with two plates containing nickel hydroxide and cadmium hydroxide, respectively. Their active material is retained by the bags formed by nickel strips, which are cut according to the size of the steel plate to promote conductivity and minimize deterioration of the positive pole.

Characteristics
  • Reliable and predictable operation
  • Resistance to mechanical and electrical excess
  • No internal corrosion
  • Optimal functionality at high temperatures
  • Low maintenance
  • Operate with electrolyte of 1,200 gr/cm3 density at 25°C
  • Compliance with IEC 60823
Applications
  • Emergency lights
  • Railway signals
  • Starting engines
  • Telecommunications
  • Fire safety system
  • Petrochemicals
  • Photovoltaic systems
Capacity chart     Contact for sale

VRPP HVM/HVL

The industrial HVM and HVL HVL nickel cadmium batteries are better than a battery with a conventional gas recombination valve, these are called ultra-low maintenance, i.e. designed for the least water use and meet the EFFICIENCY requirements of the Recombination of Gases established in the IEC 62259 + IEC 60623 standards. They comply with the requirements of International Standard IEC 60623 for nickel cadmium batteries, as well as International Standard IEC 62259.

Capacity chart HVM     Capacity chart HVL     Contact for sale

KP individual cell

Open industrial batteries with plate bag and operation with electrolyte based on potassium hydroxide, its design keeps encapsulated the active materials for greater efficiency. Maximum and minimum levels indicated on the front of the batteries.

Characteristics
  • Electrical and mechanical resistance
  • Optimal functionality at high temperatures
  • Minimal maintenance
  • Fast charging
  • Operate with electrolyte of 1,200 gr/cm3 density at 25°C
  • Compliance with IEC 60623
It has three types of individual cells to provide the best capacity option, according to the characteristics of the application and requirements of our clients.

KPH Cell with capacity from 10 Ah to 265 Ah.

Main features:
  • Thin plate
  • Greater plate area per amount of active material
  • High efficiency
Capacity chart     Contact for sale
KPM Cell with capacity from 10 Ah to 395 Ah.

Main features:
  • Plate optimized in thickness
  • Balanced range
  • Average times of discharge
Capacity chart     Contact for sale
KPL Cell with capacity from 11 Ah to 480 Ah.

Main features:
  • Thick plate
  • Amount of active material per plate area
  • Long discharge times
Capacity chart     Contact for sale
Cell Applications
  • UPS
  • Emergency lights
  • Telecommunications
  • Refineries
  • Petrochemicals
  • Train signage
  • Security systems

KB block cell

Open industrial batteries in block, , provide capacities greater than 480 Ah; contains a plate bag and operation with potassium hydroxide electrolyte, its design in the bag separators keeps the active materials encapsulated for greater efficiency. Maximum and minimum levels indicated on the front of the batteries.

Characteristics:
  • Electrical and mechanical resistance
  • Optimal functionality at high temperatures
  • Minimal maintenance
  • Fast charging
  • Operate with electrolyte of 1,200 gr/cm3 density at 25°C
  • Compliance with IEC 60623
We offer three types of block cells based on the characteristics and application specifications of our clients for an optimal selection.
KBH cells with capacities from 9 Ah to 930 Ah.

Main features:
  • Thin plate
  • Greater plate area per amount of active material
  • Short discharge times
Capacity chart     Contact for sale
KBM cells with capacities from 12 Ah to 1460 Ah.

Main features:
  • More subtle plate
  • Balanced range
  • Average times of discharge
Capacity chart     Contact for sale
KBL cells with capacities from 8 Ah to 1540 Ah.

Main features:
  • Robust plate
  • Large amount of active material per plate area
  • Long discharge times
Capacity chart     Contact for sale
Cell Applications
  • UPS
  • Emergency lights
  • Telecommunications
  • Petrochemicals
  • Train signage